APC Power Saving Back-UPS Pro RS 1500VA / 865W
Tax Information
Exc GST: 633.64GST: 63.36
Inc GST: 697.00
Estimated Availability:
10 or more units in stock
*Our stock is a mix of Suppllier and HT Stock.
All shipments are subject to our standard delivery policy.
APC Power-Saving Back-UPS Pro 900, 230V
High Performance Computer and Electronics UPS for Premium Power Protection
Includes: CD with software, Qty 1- Detachable IEC Power Cord, USB cable, User Manual, Warranty card
Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Audible alarms: Provides notification of changing utility power and UPS power conditions
Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Battery replacement without tools: Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Building Wiring Fault Indicator: This LED informs users of potentially dangerous wiring problems in the wall circuit.
Boost and Trim Automatic Voltage Regulation (AVR): Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.
Cold-start capable: Provides temporary battery power when the utility power is out.
Extendable Run Time: Additional batteries can be added to provide power to the load for an extended period of time in the event of utility supply failure.
Dataline surge protection: Provides protection of connected equipment from power surges on the data lines.
Disconnected battery notification: Warns when a battery is not available to provide backup power.
Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
LCD graphics display: Text and mimic diagrams that display modes of operation, system parameters and alarms.
Power-saving outlets: Automatically cuts power to idle equipment to conserve electricity.
Resettable circuit breaker: Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Serial connectivity: Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.
USB connectivity: Provides management of the UPS via a USB port (not available on all models).
User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Back-UPS Features & Benefits
Availability
Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.
Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Cold-start capable: Provides temporary battery power when the utility power is out.
Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
Customizable voltage sensitivity: Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.
Customizable voltage-transfer points: Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Serviceability
Resettable circuit breaker: Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Simple battery replacement: Increases UPS availability by allowing quick, easy battery replacement.
Protection
Battery and surge protected outlets: Back up and protect your hardware and data during power outages, surges and spikes.
Surge only outlets: Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Surge only outlets: Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Marketing Features
Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Boost Automatic Voltage Regulation (AVR): Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
LCD Status Display: Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Manageability
Audible alarms: Provides notification of changing utility power and UPS power conditions
LED status display: Quickly understand unit and power status with visual indicators.
Disconnected battery notification: Warns when a battery is not available to provide backup power.
USB connection: Use your PC to access additional power protection and management features for your UPS via a USB Port.
Safety
Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Technical Specifications
Output
Output power capacity: 865Watts / 1.5kVA
Max Configurable Power (Watts): 865Watts / 1.5kVA
Nominal Output Voltage: 230V
Output Frequency (sync to mains): 50/60Hz +/- 3 Hz
Topology: Line Interactive
Load Crest Factor: 3 : 1
Waveform type: Stepped approximation to a sinewave
Output Connections:
(5) IEC 320 C13 (Battery Backup)
(2) IEC Jumpers (Battery Backup)
(5) IEC 320 C13 (selector_surgetitle)
Transfer Time: 10ms typical : 12ms maximum
Input
Nominal Input Voltage: 230V
Input frequency: 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections: IEC-320 C14
Input voltage range for main operations: 176 - 294V
Input voltage range for main operations: 156 - 300V
Number of Power Cords: 1
Batteries & Runtime
Battery type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Replacement Battery: APCRBC124
Expected Battery Life (years): 3 - 5
Typical recharge time: 8hour(s)
Battery Volt-Amp-Hour Capacity: 187
RBC Quantity: 1
Communications & Management
Interface Port(s): Optional Simple Signalling RS232 cable, USB
Control panel: Multi-function LCD status and control console
Audible Alarm: Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
Surge energy rating: 441Joules
Data Line Protection: Analog phone line for phone/fax/modem/DSL (RJ-11 connector), Network line - 10/100/1000 Base-T Ethernet (RJ-45 connector)
Filtering: Full time multi-pole noise filtering :10% of IEEE surge let-thgouh : zero clamping response time: instantaneous
Physical
Maximum Height: 301MM, 30.1CM
Maximum Width: 112MM, 11.2CM
Maximum Depth: 380MM, 38.0CM
Net Weight: 12.7KG
Shipping weight: 14.3KG
Shipping Height: 387MM, 38.7CM
Shipping Width: 238MM, 23.8CM
Shipping Depth: 488MM, 48.8CM
Master Carton Units: 1.0
Colour: Black
SCC Codes: 1073130426874 8
Environmental
Operating Temperature: 0 - 40 -C
Operating Relative Humidity: 0 - 95 %
Operating Elevation: 0-9000meters
Storage Temperature: -15 - 40 -C
Storage Relative Humidity: 0 - 95 %
Storage Elevation: 0-15000meters
Audible noise at 1 meter from surface of unit: 45.0dBA
Conformance
Approvals: A-tick, C-tick, CE, GOST, GS Mark, Telepermit, TUV
Standard warranty: 2 years repair or replace
Equipment protection policy: Lifetime : 200000 AUD, Lifetime : 150000 Euros, Lifetime : 75000 GBP
Sustainable Offer Status
REACH: REACH: Contains No SVHCs
RoHS: Compliant
APC Power-Saving Back-UPS Pro 900, 230V
High Performance Computer and Electronics UPS for Premium Power Protection
Includes: CD with software, Qty 1- Detachable IEC Power Cord, USB cable, User Manual, Warranty card
Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Audible alarms: Provides notification of changing utility power and UPS power conditions
Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Battery replacement without tools: Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Building Wiring Fault Indicator: This LED informs users of potentially dangerous wiring problems in the wall circuit.
Boost and Trim Automatic Voltage Regulation (AVR): Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.
Cold-start capable: Provides temporary battery power when the utility power is out.
Extendable Run Time: Additional batteries can be added to provide power to the load for an extended period of time in the event of utility supply failure.
Dataline surge protection: Provides protection of connected equipment from power surges on the data lines.
Disconnected battery notification: Warns when a battery is not available to provide backup power.
Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
LCD graphics display: Text and mimic diagrams that display modes of operation, system parameters and alarms.
Power-saving outlets: Automatically cuts power to idle equipment to conserve electricity.
Resettable circuit breaker: Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Serial connectivity: Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.
USB connectivity: Provides management of the UPS via a USB port (not available on all models).
User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Back-UPS Features & Benefits
Availability
Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.
Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Cold-start capable: Provides temporary battery power when the utility power is out.
Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
Customizable voltage sensitivity: Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.
Customizable voltage-transfer points: Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Serviceability
Resettable circuit breaker: Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Simple battery replacement: Increases UPS availability by allowing quick, easy battery replacement.
Protection
Battery and surge protected outlets: Back up and protect your hardware and data during power outages, surges and spikes.
Surge only outlets: Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Surge only outlets: Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Marketing Features
Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Boost Automatic Voltage Regulation (AVR): Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
LCD Status Display: Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Manageability
Audible alarms: Provides notification of changing utility power and UPS power conditions
LED status display: Quickly understand unit and power status with visual indicators.
Disconnected battery notification: Warns when a battery is not available to provide backup power.
USB connection: Use your PC to access additional power protection and management features for your UPS via a USB Port.
Safety
Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Technical Specifications
Output
Output power capacity: 865Watts / 1.5kVA
Max Configurable Power (Watts): 865Watts / 1.5kVA
Nominal Output Voltage: 230V
Output Frequency (sync to mains): 50/60Hz +/- 3 Hz
Topology: Line Interactive
Load Crest Factor: 3 : 1
Waveform type: Stepped approximation to a sinewave
Output Connections:
(5) IEC 320 C13 (Battery Backup)
(2) IEC Jumpers (Battery Backup)
(5) IEC 320 C13 (selector_surgetitle)
Transfer Time: 10ms typical : 12ms maximum
Input
Nominal Input Voltage: 230V
Input frequency: 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections: IEC-320 C14
Input voltage range for main operations: 176 - 294V
Input voltage range for main operations: 156 - 300V
Number of Power Cords: 1
Batteries & Runtime
Battery type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Replacement Battery: APCRBC124
Expected Battery Life (years): 3 - 5
Typical recharge time: 8hour(s)
Battery Volt-Amp-Hour Capacity: 187
RBC Quantity: 1
Communications & Management
Interface Port(s): Optional Simple Signalling RS232 cable, USB
Control panel: Multi-function LCD status and control console
Audible Alarm: Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
Surge energy rating: 441Joules
Data Line Protection: Analog phone line for phone/fax/modem/DSL (RJ-11 connector), Network line - 10/100/1000 Base-T Ethernet (RJ-45 connector)
Filtering: Full time multi-pole noise filtering :10% of IEEE surge let-thgouh : zero clamping response time: instantaneous
Physical
Maximum Height: 301MM, 30.1CM
Maximum Width: 112MM, 11.2CM
Maximum Depth: 380MM, 38.0CM
Net Weight: 12.7KG
Shipping weight: 14.3KG
Shipping Height: 387MM, 38.7CM
Shipping Width: 238MM, 23.8CM
Shipping Depth: 488MM, 48.8CM
Master Carton Units: 1.0
Colour: Black
SCC Codes: 1073130426874 8
Environmental
Operating Temperature: 0 - 40 -C
Operating Relative Humidity: 0 - 95 %
Operating Elevation: 0-9000meters
Storage Temperature: -15 - 40 -C
Storage Relative Humidity: 0 - 95 %
Storage Elevation: 0-15000meters
Audible noise at 1 meter from surface of unit: 45.0dBA
Conformance
Approvals: A-tick, C-tick, CE, GOST, GS Mark, Telepermit, TUV
Standard warranty: 2 years repair or replace
Equipment protection policy: Lifetime : 200000 AUD, Lifetime : 150000 Euros, Lifetime : 75000 GBP
Sustainable Offer Status
REACH: REACH: Contains No SVHCs
RoHS: Compliant