- Audible alarms
Provides notification of changing utility power and UPS power conditions
- Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
- Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
- Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
- Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
- Building Wiring Fault Indicator
This LED informs users of potentially dangerous wiring problems in the wall circuit.
- Cold-start capable
Provides temporary battery power when the utility power is out.
- Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
- Disconnected battery notification
Warns when a battery is not available to provide backup power.
- Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
- PowerChute Personal Edition OS Compatibility
This software supports numerous operating systems and processors. For further information, please bra href='http://www.apc.com/wp/?um=300'click here./a
- Safety-agency approved
The UPS is UL1778 Listed
- Sine wave output
Eliminates humming and heat generated when powering tube lights and fans
- USB connectivity
Provides management of the UPS via a USB port (not available on all models).
- User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Back-UPS Pro Features & Benefits
Serviceability
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Simple battery replacement
Increases UPS availability by allowing quick, easy battery replacement.
Availability
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Customizable voltage-transfer points
Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
Customizable voltage sensitivity
Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.
Cold-start capable
Provides temporary battery power when the utility power is out.
Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Marketing features
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
Manageability
LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Protection
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes .
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Technical Specifications
Download
Output
Max Configurable Power (Watts)
720 Watts / 1.2kVA
Output Frequency (sync to mains)
50/60 Hz +/- 1 Hz Sync to mains
Topology
Line interactive
Input
Input frequency
50/60 Hz +/- 3 Hz Auto-sensing
Input voltage range for main operations
176 - 294V
Batteries & Runtime
Battery type
Lead-acid battery
Typical recharge time
16hour(s)
Expected Battery Life (years)
3 - 5
RBC Quantity
1
Battery Charge Power (Watts)
13 Watts
Runtime
View Runtime Graph
View Runtime Chart
Communications & Management
Interface Port(s)
USB
Control panel
Multifunction LCD status and control console
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
Surge energy rating
509Joules
Data Line Protection
RJ45 10/100/1000 Base-T Ethernet protection
Filtering
Full time multi-pole noise filtering : 10% of IEEE surge let-through : zero clamping response time: instantaneous
Physical
Maximum Height
260MM, 26.0CM
Maximum Width
100MM, 10.0CM
Maximum Depth
368MM, 36.8CM
Net Weight
11.7KG
Shipping weight
13.35KG
Shipping Height
359MM, 35.9CM
Shipping Width
223MM, 22.3CM
Shipping Depth
482MM, 48.2CM
Color
Black
Master Carton Dimensions (Length x Width x Height)
381 x 483 x 229MM
Master Carton Units
1.0
Master Carton Weight
14.21
SCC Codes
10731304346897
Environmental
Operating Temperature
0 - 40 -C
Operating Relative Humidity
0 - 95 (Non-condensing) %
Operating Elevation
0 - 3048meters
Storage Temperature
-15 - 45 -C
Storage Relative Humidity
0 - 95 (Non-condensing) %
Storage Elevation
0 - 15240meters
Audible noise at 1 meter from surface of unit
45.0dBA
Online thermal dissipation
16.0BTU/hr
Conformance
Approvals
A-Tick, C-Tick, CE, EAC, GS Mark, RCM, TISI
Equipment protection policy
Lifetime : 150000 euros, Lifetime : 200000 AUD, Lifetime : 75000 GBP
Standard warranty
2 years repair or replace, 3 years repair or replace for European Union countries
Sustainable Offer Status
RoHS
Compliant
Click Images To Enlarge
- Audible alarms
Provides notification of changing utility power and UPS power conditions
- Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
- Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
- Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
- Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
- Building Wiring Fault Indicator
This LED informs users of potentially dangerous wiring problems in the wall circuit.
- Cold-start capable
Provides temporary battery power when the utility power is out.
- Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
- Disconnected battery notification
Warns when a battery is not available to provide backup power.
- Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
- PowerChute Personal Edition OS Compatibility
This software supports numerous operating systems and processors. For further information, please bra href='http://www.apc.com/wp/?um=300'click here./a
- Safety-agency approved
The UPS is UL1778 Listed
- Sine wave output
Eliminates humming and heat generated when powering tube lights and fans
- USB connectivity
Provides management of the UPS via a USB port (not available on all models).
- User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Back-UPS Pro Features & Benefits
Serviceability
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Simple battery replacement
Increases UPS availability by allowing quick, easy battery replacement.
Availability
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Customizable voltage-transfer points
Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
Customizable voltage sensitivity
Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.
Cold-start capable
Provides temporary battery power when the utility power is out.
Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Marketing features
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
Manageability
LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Protection
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes .
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Technical Specifications
Download
Output
Max Configurable Power (Watts)
720 Watts / 1.2kVA
Output Frequency (sync to mains)
50/60 Hz +/- 1 Hz Sync to mains
Topology
Line interactive
Input
Input frequency
50/60 Hz +/- 3 Hz Auto-sensing
Input voltage range for main operations
176 - 294V
Batteries & Runtime
Battery type
Lead-acid battery
Typical recharge time
16hour(s)
Expected Battery Life (years)
3 - 5
RBC Quantity
1
Battery Charge Power (Watts)
13 Watts
Runtime
View Runtime Graph
View Runtime Chart
Communications & Management
Interface Port(s)
USB
Control panel
Multifunction LCD status and control console
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
Surge energy rating
509Joules
Data Line Protection
RJ45 10/100/1000 Base-T Ethernet protection
Filtering
Full time multi-pole noise filtering : 10% of IEEE surge let-through : zero clamping response time: instantaneous
Physical
Maximum Height
260MM, 26.0CM
Maximum Width
100MM, 10.0CM
Maximum Depth
368MM, 36.8CM
Net Weight
11.7KG
Shipping weight
13.35KG
Shipping Height
359MM, 35.9CM
Shipping Width
223MM, 22.3CM
Shipping Depth
482MM, 48.2CM
Color
Black
Master Carton Dimensions (Length x Width x Height)
381 x 483 x 229MM
Master Carton Units
1.0
Master Carton Weight
14.21
SCC Codes
10731304346897
Environmental
Operating Temperature
0 - 40 -C
Operating Relative Humidity
0 - 95 (Non-condensing) %
Operating Elevation
0 - 3048meters
Storage Temperature
-15 - 45 -C
Storage Relative Humidity
0 - 95 (Non-condensing) %
Storage Elevation
0 - 15240meters
Audible noise at 1 meter from surface of unit
45.0dBA
Online thermal dissipation
16.0BTU/hr
Conformance
Approvals
A-Tick, C-Tick, CE, EAC, GS Mark, RCM, TISI
Equipment protection policy
Lifetime : 150000 euros, Lifetime : 200000 AUD, Lifetime : 75000 GBP
Standard warranty
2 years repair or replace, 3 years repair or replace for European Union countries
Sustainable Offer Status
RoHS
Compliant
To add selected accessories only. click add accessories click add to cart to add both the product and selected accessories