Key Features



Audible alarms
Provides notification of changing utility power and UPS power conditions

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).

Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Boost and Trim Automatic Voltage Regulation (AVR)
Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.

Cold-start capable
Provides temporary battery power when the utility power is out.

Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.

Disconnected battery notification
Warns when a battery is not available to provide backup power.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

USB connectivity
Provides management of the UPS via a USB port (not available on all models).

User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Back-UPS Pro Features & Benefits



Marketing Features
Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.

Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Serviceability
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)

Simple battery replacement
Increases UPS availability by allowing quick, easy battery replacement.

Protection
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.

Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.

Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.

Availability
Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.

Cold-start capable
Provides temporary battery power when the utility power is out.

Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Customizable voltage-transfer points
Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.

Customizable voltage sensitivity
Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).

Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Manageability
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.

Disconnected battery notification
Warns when a battery is not available to provide backup power.

Audible alarms
Provides notification of changing utility power and UPS power conditions

LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.




Specifications



Output


Max Configurable Power (Watts)
960Watts / 1.6kVA

Output Frequency (sync to mains)
50/60 Hz +/-1 Hz

Topology
Line Interactive

Input


Input frequency
50/60 Hz +/- 3 Hz (auto sensing)

Input voltage range for main operations
176 - 294V

Batteries & Runtime


Battery type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof

Typical recharge time
16hour(s)

Expected Battery Life (years)
3 - 5

RBC Quantity
1

Battery Volt-Amp-Hour Capacity
180

Communications & Management


Interface Port(s)
USB

Control panel
Multi-function LCD status and control console

Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm

Surge Protection and Filtering


Surge energy rating
509Joules

Data Line Protection
RJ45 10/100/1000 Base-T Ethernet protection

Filtering
Full time multi-pole noise filtering :10% of IEEE surge let-through : zero clamping response time: instantaneous

Physical


Maximum Height
100MM, 10.0CM

Maximum Width
250MM, 25.0CM

Maximum Depth
382MM, 38.2CM

Net Weight
10.2KG

Shipping weight
11.85KG

Shipping Height
330MM, 33.0CM

Shipping Width
485MM, 48.5CM

Shipping Depth
225MM, 22.5CM

Color
Black

Environmental


Operating Temperature
0 - 40 -C

Operating Relative Humidity
0 - 95 (non-condensing) %

Operating Elevation
0-3000meters

Storage Temperature
-15 - 45 -C

Storage Relative Humidity
0 - 95 (non-condensing) %

Storage Elevation
0-15000meters

Audible noise at 1 meter from surface of unit
45.0dBA

Online thermal dissipation
21.5BTU/hr

Conformance


Approvals
A-tick, C-tick, CE, EAC, GS Mark, RCM, TISI

Equipment protection policy
Lifetime : 200000 AUD, Lifetime : 150000 Euros, Lifetime : 75000 GBP

Standard warranty
2 years repair or replace, 3 years repair or replace for European Union countries

Sustainable Offer Status


RoHS
Compliant

REACH
REACH: Contains SVHCs

Proposition 65 Warning
Available in Documentation tab




 

Key Features



Audible alarms
Provides notification of changing utility power and UPS power conditions

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).

Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Boost and Trim Automatic Voltage Regulation (AVR)
Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.

Cold-start capable
Provides temporary battery power when the utility power is out.

Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.

Disconnected battery notification
Warns when a battery is not available to provide backup power.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

USB connectivity
Provides management of the UPS via a USB port (not available on all models).

User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Back-UPS Pro Features & Benefits



Marketing Features
Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.

Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

Serviceability
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)

Simple battery replacement
Increases UPS availability by allowing quick, easy battery replacement.

Protection
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.

Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.

Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.

Availability
Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.

Cold-start capable
Provides temporary battery power when the utility power is out.

Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Customizable voltage-transfer points
Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.

Customizable voltage sensitivity
Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).

Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Manageability
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.

Disconnected battery notification
Warns when a battery is not available to provide backup power.

Audible alarms
Provides notification of changing utility power and UPS power conditions

LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.




Specifications



Output


Max Configurable Power (Watts)
960Watts / 1.6kVA

Output Frequency (sync to mains)
50/60 Hz +/-1 Hz

Topology
Line Interactive

Input


Input frequency
50/60 Hz +/- 3 Hz (auto sensing)

Input voltage range for main operations
176 - 294V

Batteries & Runtime


Battery type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof

Typical recharge time
16hour(s)

Expected Battery Life (years)
3 - 5

RBC Quantity
1

Battery Volt-Amp-Hour Capacity
180

Communications & Management


Interface Port(s)
USB

Control panel
Multi-function LCD status and control console

Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm

Surge Protection and Filtering


Surge energy rating
509Joules

Data Line Protection
RJ45 10/100/1000 Base-T Ethernet protection

Filtering
Full time multi-pole noise filtering :10% of IEEE surge let-through : zero clamping response time: instantaneous

Physical


Maximum Height
100MM, 10.0CM

Maximum Width
250MM, 25.0CM

Maximum Depth
382MM, 38.2CM

Net Weight
10.2KG

Shipping weight
11.85KG

Shipping Height
330MM, 33.0CM

Shipping Width
485MM, 48.5CM

Shipping Depth
225MM, 22.5CM

Color
Black

Environmental


Operating Temperature
0 - 40 -C

Operating Relative Humidity
0 - 95 (non-condensing) %

Operating Elevation
0-3000meters

Storage Temperature
-15 - 45 -C

Storage Relative Humidity
0 - 95 (non-condensing) %

Storage Elevation
0-15000meters

Audible noise at 1 meter from surface of unit
45.0dBA

Online thermal dissipation
21.5BTU/hr

Conformance


Approvals
A-tick, C-tick, CE, EAC, GS Mark, RCM, TISI

Equipment protection policy
Lifetime : 200000 AUD, Lifetime : 150000 Euros, Lifetime : 75000 GBP

Standard warranty
2 years repair or replace, 3 years repair or replace for European Union countries

Sustainable Offer Status


RoHS
Compliant

REACH
REACH: Contains SVHCs

Proposition 65 Warning
Available in Documentation tab